ELECTRICAL Current (each of these current profiles causes a maximum 30ºC temperature rise) ►
Continuous Rated Current (CRC) (per IEC 61984 and UL1977) 500 amp ►
Current Profile #2 – 50% CRC for 60min + 1 sec peak + 50% CRC for 60 min 3,000 amp ►
Current Profile #3 – 50% CRC for 60min + 10 sec peak + 50% CRC for 60 min 2,000 amp ►
Current Profile #4 – 50% CRC for 60min + 30 sec peak + 50% CRC for 60 min 1,250 amp ►
Current Profile #5 – 50% CRC for 60min + 60 sec peak + 50% CRC for 60 min 1,000 amp Voltage ►
Rated Voltage (volts, continuous) 2,000 ►
Minimum Dielectric Withstanding Voltage (volts, AC or DC) 5,000 Contact Resistance Max (Micro Ohms) 70 MECHANICAL Wire Size Range ►
Maximum Wire Size ►
Terminal Only 450 MCM (230 mm²) ►
With Flexible Cover 4/0 (110 mm²) ►
With Rigid Short Snap-On Cover 3/0 (80 mm²) ►
With Rigid Long, Snap-On Cover 2 AWG (35 mm²) ►
Maximum Terminal Lug Tongue Width (inches) ►
With Flexible Cover 1.10 ►With Rigid Short Snap-On Cover 0.91 ►
With Rigid Long, Snap-On Cover 0.70 Minimum Panel Thickness (inches) 0.025 ►
With Standard Kit Components IP65 ►
With Optional Gasket IP68 Operating Temperature (ºC) ►
Terminal and Rigid Covers -40º to 125º ►
Flexible Covers -40º to 90º Flammability Rating (per UL94) ►
Terminal and Rigid Covers 5VA ►
Flexible Covers V-0 Mechanical Shock 50gs – 3 axes Vibration 10gs – 3 axes
CERTIFICATIONS UL and CE Conformance Certificates are downloadable from Rebling.com
RoHS Compliance All parts itemized on this datasheet are RoHS compliant